Used / Waste Oil Testing
Used-oil characterisation – metals, PCBs, flash point and recyclability per Hazardous Waste Rules.
About Used / Waste Oil Testing
Used and waste oil is a regulated hazardous waste, and whether it can be recycled, reprocessed or must be incinerated depends on its characterisation. CVR Labs tests used lubricating oil, waste oil and transformer oil for heavy metals, total halogens and PCBs, flash point, water and sediment content and the parameters that define recyclability under the Hazardous and Other Wastes Rules.
PCB content is the critical gate for transformer and older oils — above the threshold the oil is treated as PCB waste with strict handling. Reports give recyclers, generators and registered re-refiners the documented basis to classify a batch and route it lawfully.

Signature tests under Used / Waste Oil Testing
The checks clients most often ask for with this service — we build the right sub-panel around your product and standard.
What we analyse under Used / Waste Oil Testing
The parameter groups below are drawn from this service's own accredited scope; the full searchable list follows.
Total halogens gate recyclability
High chlorine/halogen content signals chlorinated solvents or PCB contamination — the key screen before oil can be re-refined.
Recyclability is a spec, not a guess
Flash point, halogens, water and sediment define whether waste oil can be re-refined or must be destroyed.
Used oil is regulated waste
Under the Hazardous Waste Rules, generators must characterise used oil to document lawful recycling or disposal.
Safety & flammability
Viscosity & physical
Contaminants & recyclability
Degradation & acidity
Used / Waste Oil Testing — parameters & methods
| Parameter / Test | Method / Standard |
|---|---|
| Acid number | ASTM-D 974-08 |
| Ash content | ASTM D:482-07 |
| Base number | ASTM-D 974-08 |
| Density | ASTM D:1298-99 |
| Fire point | ASTM D:93-08 |
| Flash point | ASTM D:93-08 |
| Gasoline Diluents | ASTM D:322-97 |
| Gross Calorific Value | CVR/WT/SOP/025ASTM D 240-02 |
| Neutralization number | ASTM-D 974-08 |
| Saponification Value | ASTM-D 94-07 |
| Sediment | ASTM D 1796-04 |
| Sulphur | ASTM D:129-00 |
| Total Halogens as Cl | CVR/WT/SOP/027 |
| Viscosity 100° C | ASTM D 445-06 |
| Viscosity 40° C | ASTM D 445-06 |
| Viscosity at 50°C | ASTM D 445-06 |
| Water Content | IS 2720 Part 2 Section 1 ( Oven Drying Method)ASTM D:95 |
How Used / Waste Oil Testing is tested
Reference methods applied
Where more than one standard applies, the appropriate method is selected for each sample and regulatory requirement. The physico-chemical oil parameters follow the relevant ASTM D-series test methods; total halogens and gross calorific value run to validated in-house CVR SOPs, all within the accredited scope.
Accreditations covering Used / Waste Oil Testing
See the Accreditations & Scope page for full certificate details.
Samples we accept for Used / Waste Oil Testing
From enquiry to accredited report
Enquiry & Scope
Share your site, regulatory driver and parameters; we define the plan.
Field Sampling
Trained personnel sample on-site per CPCB/IS protocols.
Lab Analysis
Accredited instruments with full chain-of-custody and QC.
Technical Review
Results checked against statutory limits and approved.
Accredited Report
Audit-ready report formatted for regulatory submission.
Used / Waste Oil Testing — frequently asked questions
Is Used / Waste Oil Testing NABL-accredited at CVR Labs?
Why test used oil for PCBs?
What decides if waste oil can be recycled?
Who needs used-oil testing?
What samples do you accept for Used / Waste Oil Testing?
What parameters are included in Used / Waste Oil Testing?
Ready to test with an accredited laboratory?
NABL ISO/IEC 17025:2017 · ISO 9001 · ISO 45001 · CPCB · BIS — trusted since 1999.