Home / Services / Environmental Monitoring / Indoor Air Quality Testing

Indoor Air Quality Testing

Work-environment and indoor air assessment – dust, gases, VOCs, CO2 and thermal comfort.

Environmental Monitoring

About Indoor Air Quality Testing

Indoor and workplace air quality affects both regulatory compliance and the health and productivity of occupants, and the relevant parameters differ from outdoor air. CVR Labs assesses offices, hospitals, cleanrooms, production halls and enclosed workplaces for respirable dust, CO2, CO, VOCs, formaldehyde, ozone and the temperature/humidity comfort parameters, plus the specific gases and vapours present in a given work environment.

For occupational settings we benchmark exposures against work-environment norms; for offices and healthcare we apply indoor-air-quality guidance for CO2 ventilation adequacy and pollutant build-up. The result tells a facilities or EHS manager whether ventilation, filtration and controls are actually keeping indoor air within acceptable limits.

Indoor Air Quality Testing at CVR Labs Chennai
Most Requested

Signature tests under Indoor Air Quality Testing

The checks clients most often ask for with this service — we build the right sub-panel around your product and standard.

Respirable dust (PM)CO2 & COVOCs & formaldehydeOzoneTemperature & humidityWorkplace-specific gases
Test Coverage

What we analyse under Indoor Air Quality Testing

The parameter groups below are drawn from this service's own accredited scope; the full searchable list follows.

Indoor air is its own problem

CO2 build-up, VOCs and inadequate ventilation degrade indoor air independently of outdoor quality — and only indoor monitoring reveals it.

Workplaces have exposure norms

Work-environment air must keep dust, gases and vapours within occupational limits; monitoring verifies that engineering controls work.

Comfort and health are measurable

Temperature, humidity and CO2 quantify ventilation adequacy in offices, schools and healthcare — turning complaints into data.

Comfort & physical parameters

% Relative HumidityTemperatureHeat Stress (WBGT)IlluminationVelocityOxygen as (O2)

Gases & particulates

Carbon DioxideCarbon monoxideAmmonia as (NH3)Hydrogen Sulphide (H2S)Sulphur dioxide (SO2)Fine Particulate Matter (PM2.5/PM10)

VOCs & chlorinated organics

Total VOCsBenzeneTolueneXyleneFormaldehydeVinyl Chloride

Heavy & trace metals

Lead as PbArsenic as AsCadmium as CdMercury as HgHexavalent Chromium Cr(VI)Nickel as Ni
NABL Scope of Accreditation

Indoor Air Quality Testing — parameters & methods

Parameter / TestMethod / Standard
% Relative Humidity CVR/ENV/SOP/11
1,1,1,2-Tetrachloroethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,1,1-Trichloroethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,1,2,2-Tetrachloroethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,1,2-Trichloroethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,1-Dichloroethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,1-Dichloroethene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,1-Dichloropropene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2,3-Trichlorobenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2,3-Trichloropropane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2,4-Trichlorobenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2,4-Trimethylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2-Dibromo-3- chloropropane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2-Dibromoethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2-Dichlorobenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2-Dichloroethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,2-Dichloropropane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,3,5-Trimethylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,3-Dichlorobenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,3-Dichloropropane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
1,4-Dichlorobenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
2,2-Dichloropropane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
2-Chlorotoluene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
4-Chlorotoluene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
4-Isopropyltoluene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Aluminium as Al IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Ammonia as (NH3) IS 5182 (Part 25) Indophenol methodIS 11255 (Part 6)NIOSH - 6015
Antimony as Sb IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Arsenic as As CVR/INS/SOP/ICPMS/003IS 3025 (PART 65)CVR/INS/SOP/ICPMS/001
Barium as Ba IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Benzene CVR/INS/SOP/GCMSMS/018IS 5182 (Part 11), 2011CVR/INS/SOP/GCMSMS/026
Beryllium as Be CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001CVR/INS/SOP/ICPMS/002
Boron as B CVR/INS/SOP/ICPMS/001CVR/INS/SOP/ICPMS/002CVR/INS/SOP/ICPMS/012
Bromobenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Bromochloromethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Bromodichloromethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Bromoform CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Bromomethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Cadmium as Cd CVR/INS/SOP/ICPMS/003IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005
Carbon Dioxide CVR/ENV/SOP/03
Carbon monoxide CVR/ENV/SOP/01CVR/ENV/SOP/03
Carbon Tetrachloride CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Chlorobenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Chloroethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Chloroform CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Chloromethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Chromium as Cr IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
cis-1,2-Dichloroethene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
cis-1,3-Dichloropropene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Cobalt as Co CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001IS 3025 (PART 65)
Copper as Cu CVR/INS/SOP/ICPMS/003IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005
Dibromochloromethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Dibromomethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Dichlorodifluoromethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Ethylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Fine Particulate Matter EPA Compendium Method IP-10
Fine Particulate Matter (PM 10) CVR/ENV/SOP/012
Fine Particulate Matter (PM 2.5) IS 5182 (Part 24)CVR/ENV/SOP/012
Formaldehyde NIOSH 2016NIOSH 3500
Heat Stress (Wet Bulb Globe Temperature Index) CVR/ENV/SOP/013
Hexachlorobutadiene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Hexavalent Chromium as Cr(VI) NIOSH 7600
Hydrogen Sulphide as (H2S) IS 5182 (Part 7)NIOSH - 6013
Illumination CVR/ENV/SOP/07
Iron as Fe 3500-Fe B APHA 24th EditionIS 3025 (Part 53)CVR/INS/SOP/ICPMS/005
Isopropylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Lead as Pb CVR/INS/SOP/ICPMS/003IS 3025 (PART 65)CVR/INS/SOP/ICPMS/001
m- & p-Xylenes CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Manganese as Mn IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Mercury as Hg AOAC 22nd Edition : 2015.01EPA 200.8EPA 29
Methylene Chloride CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Molybdenum as Mo IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Naphthalene CVR/INS/SOP/GCMSMS/003CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026
n-Butylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Nickel as Ni CVR/INS/SOP/ICPMS/003IS 3025 (PART 65)CVR/INS/SOP/ICPMS/001
Nitric Oxide as (NO) and Nitrogen dioxide (NO2) NIOSH-6014
n-Propylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Oil Mist, Mineral as (CnH2n+2) NIOSH-5026
Oxygen as (O2) CVR/ENV/SOP/09CVR/ENV/SOP/008
o-Xylene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Particulate Method otherwise Not regulated Total( Total Aerosol mass) NIOSH-0500
Respirable Aerosol mass( Respirable Particulate) NIOSH-0600
sec-Butylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Selenium as Se IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Silver as Ag IS 3025 (PART 65)CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Strontium as Sr CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001CVR/INS/SOP/ICPMS/012
Styrene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Sulphur dioxide as (SO2) CVR/ENV/SOP/014NIOSH-6004IS/ISO 8573-6
t-Butylbenzene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Temperature EPA-454/R-99-005CVR/ENV/SOP/112550 B APHA 24th Edition
Tetrachloroethene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Thallium as Tl CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001CVR/INS/SOP/ICPMS/002
Thorium as Th CVR/INS/SOP/ICPMS/001
Tin as Sn CVR/INS/SOP/ICPMS/003CVR/INS/SOP/ICPMS/005
Titanium as Ti CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001
Toluene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Total Volatile Organic Compounds CVR/ENV/SOP/015
trans-1,2-Dichloroethene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
trans-1,3-Dichloropropene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Trichloroethene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Trichlorofluoromethane CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Vanadium as V CVR/INS/SOP/ICPMS/005CVR/INS/SOP/ICPMS/001CVR/INS/SOP/ICPMS/002
Velocity CVR/ENV/SOP/10
Vinyl Chloride CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Xylene CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025
Zinc as Zn CVR/INS/SOP/ICPMS/003IS 3025 (PART 65)
Zirconium as Zr CVR/INS/SOP/ICPMS/001
Need a parameter that isn't listed? Share your product and requirement and our technical team will confirm the applicable method, standard and turnaround, and advise whether it falls within our NABL scope. Contact our technical team →
Methods & Standards

How Indoor Air Quality Testing is tested

Reference methods applied

IS 3025 (PART 65)NIOSH 2016 / 3500 / 6013 / 6014 / 7600IS 5182 (Part 25) Indophenol methodIS 11255 (Part 6)IS 5182 (Part 11), 2011EPA Compendium Method IP-10IS 5182 (Part 24)IS 5182 (Part 7)

Where more than one standard applies, the appropriate method is selected for each sample and regulatory requirement. Validated in-house CVR SOPs on GC-MS/MS, LC-MS/MS and ICP-MS are part of the accredited scope.

Accreditation & Recognition

Accreditations covering Indoor Air Quality Testing

See the Accreditations & Scope page for full certificate details.

NABL
CPCB
ISO 45001
Samples we accept

Samples we accept for Indoor Air Quality Testing

Officeshospitalscleanroomsworkplacesenclosed environments
How It Works

From enquiry to accredited report

Enquiry & Scope

Share your site, regulatory driver and parameters; we define the plan.

Field Sampling

Trained personnel sample on-site per CPCB/IS protocols.

Lab Analysis

Accredited instruments with full chain-of-custody and QC.

Technical Review

Results checked against statutory limits and approved.

Accredited Report

Audit-ready report formatted for regulatory submission.

FAQ

Indoor Air Quality Testing — frequently asked questions

Is Indoor Air Quality Testing NABL-accredited at CVR Labs?
Yes. Indoor Air Quality Testing is performed under CVR Labs' NABL ISO/IEC 17025:2017 accreditation (Cert. NABLT0626TN18226) at our Chennai laboratory, with traceable, audit-ready reports accepted for compliance and submission.
What does indoor air quality testing measure?
Respirable dust, CO2, CO, VOCs, formaldehyde, ozone and thermal-comfort parameters, plus any workplace-specific gases or vapours relevant to the environment.
Can you assess workplace exposure?
Yes. Work-environment air is benchmarked against occupational limits to verify that ventilation and engineering controls keep exposures acceptable.
Is this useful for offices and hospitals?
Yes. CO2, VOC and comfort monitoring assesses ventilation adequacy and pollutant build-up in offices, schools, cleanrooms and healthcare settings.
What samples do you accept for Indoor Air Quality Testing?
We routinely handle Offices, hospitals, cleanrooms, workplaces, enclosed environments. Share your exact sample type and target standard and our technical team will confirm the required quantity, method and turnaround.
What parameters are included in Indoor Air Quality Testing?
The Indoor Air Quality Testing panel covers 107 accredited parameters such as % Relative Humidity, 1,1,1,2-Tetrachloroethane, 1,1,1-Trichloroethane, 1,1,2,2-Tetrachloroethane and 1,1,2-Trichloroethane. The full searchable list is on this page — tell us your target and we'll map the right sub-panel for your sample.

Ready to test with an accredited laboratory?

NABL ISO/IEC 17025:2017 · ISO 9001 · ISO 45001 · CPCB · BIS — trusted since 1999.