VOC Monitoring
Speciated volatile organic compound and compressed-gas analysis by GC-MS.
About VOC Monitoring
Volatile organic compounds drive both health risk and fugitive product loss, and they require speciated analysis — knowing total VOC is rarely enough when a specific compound carries the limit. CVR Labs identifies and quantifies individual VOCs by GC-MS, covering BTEX (benzene, toluene, ethylbenzene, xylenes), chlorinated solvents and the wider volatile suite in workplace air, fence-line monitoring, process vents and compressed gases.
Sampling uses sorbent tubes, canisters or impingers matched to the compound and setting, with thermal desorption or solvent extraction at the laboratory. Whether the driver is occupational exposure to benzene, a fence-line complaint or LDAR support, results are reported compound-by-compound against the applicable limit.

Signature tests under VOC Monitoring
The checks clients most often ask for with this service — we build the right sub-panel around your product and standard.
What we analyse under VOC Monitoring
The parameter groups below are drawn from this service's own accredited scope; the full searchable list follows.
Speciation is essential
Benzene carries a far stricter limit than other aromatics; only compound-by-compound GC-MS quantification tells you which VOC is the problem.
VOCs are health and loss
Volatiles are both an exposure hazard and lost product/feedstock; monitoring serves safety and process economics together.
Sampling must fit the compound
Sorbent tubes, canisters and impingers each suit different VOCs and settings — correct media selection makes the result valid.
BTEX & aromatics
Alkylbenzenes & substituted aromatics
Chlorinated & halogenated solvents
Brominated & trihalomethanes
VOC Monitoring — parameters & methods
| Parameter / Test | Method / Standard |
|---|---|
| 1,1,1,2-Tetrachloroethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,1,1-Trichloroethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,1,2,2-Tetrachloroethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,1,2-Trichloroethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,1-Dichloroethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,1-Dichloroethene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,1-Dichloropropene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2,3-Trichlorobenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2,3-Trichloropropane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2,4-Trichlorobenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2,4-Trimethylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2-Dibromo-3- chloropropane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2-Dibromoethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2-Dichlorobenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2-Dichloroethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,2-Dichloropropane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,3,5-Trimethylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,3-Dichlorobenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,3-Dichloropropane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 1,4-Dichlorobenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 2,2-Dichloropropane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 2-Chlorotoluene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 4-Chlorotoluene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| 4-Isopropyltoluene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Benzene | CVR/INS/SOP/GCMSMS/018IS 5182 (Part 11), 2011CVR/INS/SOP/GCMSMS/026 |
| Bromobenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Bromochloromethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Bromodichloromethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Bromoform | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Bromomethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Chlorobenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Chloroethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Chloroform | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Chloromethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| cis-1,2-Dichloroethene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| cis-1,3-Dichloropropene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Dibromochloromethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Dibromomethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Dichlorodifluoromethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Ethylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Hexachlorobutadiene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Isopropylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| m- & p-Xylenes | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Naphthalene | CVR/INS/SOP/GCMSMS/003CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026 |
| n-Butylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| n-Propylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| o-Xylene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| sec-Butylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Styrene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| t-Butylbenzene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Tetrachloroethene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Toluene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| trans-1,2-Dichloroethene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| trans-1,3-Dichloropropene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Trichloroethene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Trichlorofluoromethane | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Vinyl Chloride | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
| Xylene | CVR/INS/SOP/GCMSMS/018CVR/INS/SOP/GCMSMS/026CVR/INS/SOP/GCMSMS/025 |
How VOC Monitoring is tested
Reference methods applied
Where more than one standard applies, the appropriate method is selected for each sample and regulatory requirement. Individual VOCs are speciated and quantified by GC-MS/MS under validated in-house CVR SOPs, with benzene also covered by IS 5182 (Part 11); samples are collected on sorbent tubes, canisters or impingers and thermally desorbed or extracted at the laboratory — all within the accredited scope.
Accreditations covering VOC Monitoring
See the Accreditations & Scope page for full certificate details.
Samples we accept for VOC Monitoring
From enquiry to accredited report
Enquiry & Scope
Share your site, regulatory driver and parameters; we define the plan.
Field Sampling
Trained personnel sample on-site per CPCB/IS protocols.
Lab Analysis
Accredited instruments with full chain-of-custody and QC.
Technical Review
Results checked against statutory limits and approved.
Accredited Report
Audit-ready report formatted for regulatory submission.
VOC Monitoring — frequently asked questions
Is VOC Monitoring NABL-accredited at CVR Labs?
Do you speciate individual VOCs?
Where can VOC monitoring be applied?
How are VOC samples collected?
What samples do you accept for VOC Monitoring?
What parameters are included in VOC Monitoring?
Ready to test with an accredited laboratory?
NABL ISO/IEC 17025:2017 · ISO 9001 · ISO 45001 · CPCB · BIS — trusted since 1999.